Connected to the CT-V900-A controller’s expander bus, each CA-A480-A can control up to 16 oors. The CA-A480-A oor control
relays can be interfaced directly with an elevator’s oor control buttons. When a valid card is presented, the appropriate oor control
relays will become enabled allowing the cardholder to select the desired oor.
CA-A480-A I Elevator Controller
CA-A110-P I Lock Control Module
CA-A482-P I Destination Reporting Module
Connected on top of the CA-A480-A, the DRM has 16 Floor Selection inputs, one for each oor control relay of the CA-A480-A
elevator controller. Once a card is presented, the user can only select one oor. Once the oor is selected, all other oor selection
buttons are de-activated. The user must present his card again in order to select another oor. Each card swipe and individual oor
selection is recorded by the system.
The CA-A110-P has been designed to reduce installation time and simplify the connection of electromagnetic locks or in
conjunction with door strikes. It is directly inserted into the CT-V900-A’s lock terminals.
• 16 Form “C” oor control relays (15A/28Vdc, N.C./N.O.)
• 1 Fire control input + 1 Tamper input
• Control up to 64 oors and 2 elevator cabs
• Destination reporting (requires CA-A482-P)
• E-Bus connectivity to the CT-V900-A up to 1220m
• Backup battery with selectable battery charge current
• On-board 12Vdc power supply
• Fully supervised (tamper, low battery and AC failure) with LED display
• Up to 8 CA-A480-A controller per CT-V900-A controller
• Connects directly onto the CA-A480-A elevator controller
• One-card swipe, one-oor operation
• User must present a valid card to select a oor button.
• 16 oor-selection inputs and LED indicators
• Records Valid and Invalid oor selections
• Power input: 5Vdc
• Current consumption: 28mA (typical), 108mA (max)
• DC input activation: 15Vdc (minimum), 165Vdc (max)
• Connection method: 14-way Flat Cable to CA-A480-A
• Simplies the installation of dual-locking doors
(2 mag locks or combination of a mag lock and a door strike)
• Lock outputs: 2 form C relays rated at 5A/12Vdc, N.C./N.O.
• 2 relay status LEDs
• Connects directly to the CT-V900-A lock output terminals
• Current consumption: 100mA