5
cdvi.co.uk
cdvigroup.com
• Control 2 doors/readers per CT-V900-A (up to 8 using three
CA-A470-A 2-door expander modules, see page 6)
• On-board card database
• 256 Schedules
• 256 Access Levels
• 2048 Event Buffer
• Fully distributed database architecture (access decisions made locally)
• Upgradable rmware - Upload rmware via the computer
• E-Bus technology: expander modules can be up to 1220m from the
CT-V900-A
• Supports most common Wiegand formats, magnetic Stripe Track II
ABA and 9 keypad formats, including BCD
• Easy maintenance with snap-off terminal blocks
• Lithium battery protection in case of complete power failure
• Comprehensive LED status indicators
CT-V900-A I 2-Door Controller
The CT-V900-A is at the heart of every Centaur access control system. The Centaur Server, hardware expander modules,
multi-purpose inputs, card readers, keypads and outputs are connected directly to the CT-V900-A. Multi-controller systems
are joined together via the RS-485 communication bus or TCP/IP. Distributed database architecture allows each controller
to make split-second decisions without the need of the server/computer. Lightning-quick, robust and remarkable stability
make the CT-V900-A the professional’s choice.
Output Specications:
Lock Outputs: 2 selectable fail safe/fail secure (12 or
24Vdc)
Relay Outputs: 2 Form C Dry Contact 5A/28Vdc
Reader Outputs: Six 50mA Open collector outputs
(Red/Green LEDs, Buzzer)
Input Specications:
Reader Inputs/Ports: 2
Keypad Inputs/Ports: 2
Multi-purpose Inputs: 16 (using ATZ 2R/3R)
Physical Specications:
Cabinet size: 39cm (H) x 33cm (W) x 10cm (D)
PCB dimensions: 24.5cm x 20.2cm
Environment: 5°C to 55°C
Electrical Specications:
Power input: 24Vac, 75VA or higher, 50/60Hz
Supply current: 2.5A switch mode
Battery backup: Two 12Vdc, 7Ah, gel cell batteries
Communication:
Plug and play technology
RS-485 E-Bus for expander modules, RS-485, TCP/IP,
RS-232 or modem
On-board Protection:
Auxiliary outputs: 2.5A (24Vdc), 1A (12Vdc & 5Vdc)
fuseless protection
AC protection: 5A fuse
Battery reversal: 7A fuse
INTEGRATED ACCESS CONTROL