1.1.1.40 Insulation test
Set the multimeter to the resistor range to measure the resistance between the bolt of the pressure plate
assembly and the cabinet. If the circuit is disconnected, end the installation. Otherwise, it indicates the cabinet is
not insulated from the supports. In this case, remove all the pressure plate assemblies to check if any insulation
sleeves or pads of the supports are missing or any insulation parts are damaged. Then install the pressure plate
assemblies again and repeat the insulation test.